Middleby Marshall PS636 Range User Manual


 
SECTION 2
INSTALLATION
WARNING
DO NOT USE CONDUIT FOR
GROUND CONNECTION.
CAUTION
IT IS RECOMMENDED THAT THE OVEN
BE PLACED UNDER A VENTILATION
HOOD FOR ADEQUATE AIR SUPPLY
AND VENTILATION.
ELECTRIC SUPPLY TO BE
PROVIDED BY CUSTOMER
CIRCUIT BREAKER
A seperate circuit breaker with lockout/tagout electrical
shutoff is required for each, seperately wired oven.
See breaker sizing requirements below:
ELECTRICAL SPECIFICATIONS
NOTE: Please refer to page 2, Electrical Specifications
chart and your units data plate information, for more
detailed information.
Do
NOT
use conduit for ground.
or
EXPORT: CE MODEL
POWER RATING
UTILITY ROUGH-IN DIMENSIONS AND POSITIONING
SUPPLY WIRE
Supply wire size must be in accordance with the
National Electrical Code (current edition) and must be in
compliance with local codes.
SUGGESTED
If space permits, service should be located near the
control console end of the oven(s) to allow convenient
access to safety switches.
II. VENTILATION GUIDELINES
Use of a ventilation hood is not required for proper
operation, but installation must conform with all local
codes and regulations.
Local codes and conditions vary greatly from one area to
another and must be complied with. Following are the
suggested requirements for good ventilation. Please re-
member these are recommendations or guidelines, you
may have a special condition or problem that will require
the services of a ventilation engineer or specialist. Proper
ventilation is the oven owner’s responsibility. Improper
ventilation can inhibit oven performance.

MM
/
.
/
&
&
/
.
/
&
&

MM
3UGGESTEDDIMENSIONSARESHOWNUTILITYCODE
REQUIREMENTSSUPERSEDEANYFACTORSSHOWN
4O/VEN
4O/VEN
Suggested dimensions are shown; utility code
requirements supersede any factors shown.
FOR PS636-SERIES OVENS
Figure 2-9. Typical Oven Installation
240V, 60 Hz, 19.8 kW, 60A Service
208V, 60 Hz, 19.8 kW, 70A Service
DOMESTIC:
208V, 50/60 Hz, 19.8 kW, 30A Service
230-240V, 50/60Hz, 18.2/19.8 kW, 30A Service
Do NOT
use conduit for ground.
19.8 kW Standard
380V, 50/60 Hz, 19.8 kW, 40A Service
400-416V, 50/60 Hz, 18.3-19.8 kW, 30A Service
230V (400Y), 50/60 Hz, 18.2 kW, 30A Service
5-WIRE SYSTEM (L1, L2, L3, N & GROUND)
4-WIRE SYSTEM (L1,L2, L3 & GROUND)
4-WIRE SYSTEM (L1,L2, L3 & GROUND)
11