Ventilation outlet for recirculation mode. A gap of at least 300 mm must be
maintained between the top of the cooker hood and the ceiling or any furniture
above it.
Connection for air extraction 150 mm, or 125 mm with reducing collar.
Please observe installation positions for the socket and for the ducting outlet
shown on the relevant drawings when using the DADC 6000 tower.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker
hood is as follows, unless a greater distance is specified by the manufacturer of
your cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance Minimum distance S
Electric hob 450 mm
Electric grill, deep fat fryer (electric) 650 mm
Multi-burner gas hob,
total output 12.6 kW, no burner > 4.5 kW
650 mm
Multi-burner gas hob,
total output > 12.6 kW and 21.6 kW,
no burner > 4.8 kW.
760 mm
Multi-burner gas hob,
total output > 21.6 kW,
or multi-burner gas hob where one burner > 4.8 kW.
Not possible
Single burner gas hob, output 6 kW. 650 mm
Single burner gas hob, output > 6 kW and 8.1 kW. 760 mm
Single burner gas hob, output > 8.1 kW Not possible