Miele DA217-3 Ventilation Hood User Manual


 
^
Remove the protective foil from
chimney extension.
^ Bend the top hanging tabs 45°
inwards. This will make installing the
extension easier. Be careful of sharp
edges.
Recirculation Air extraction
^
Pull the chimney extension slightly
outwards and snap over the upper
retaining plate B.
When installing for recirculation, ensure
that the vents are positioned so they
line up with the diverter.
^
Screw the extension piece firmly to
the upper retaining plate using two
3.9 x 7.5 mm screws.
^
Cover the screws with the supplied
cap covers.
^
Only for recirculation:
With the slats pointing downwards,
install the recirculation vents through
the extension piece and into the
diverter.
Installation
39