Miele DA239-3 Ventilation Hood User Manual


 
Attaching the hood and motor
assembly to the wall
The chimney and chimney extension
are attached to the wall using 2
retaining plates. The motor assembly is
attached separately using 4 screws.
To layout the loctaions for the plates
and motor assembly:
^
Draw a vertical line, centered on the
cooktop, on the wall where the hood
will be installed.
^
Mark the location of the 2 motor
assembly support screws S + 10
1
/
4
"
(260 mm) above the cooktop, and
4
15
/
16
" (125 mm) to the right and left
of the centerline.
^
Layout the location of the lower
retaining plate screw directly on the
centerline, S + 19
1
/
2
" (495 mm)
above the cooktop.
^ Hold the upper retaining plate flush
against the ceiling so that the
centerline passes through the notch
on its lower edge. Making sure the
plate is level, mark the location of the
2 mounting screws.
Installation
28