Miele DA362-110 Ventilation Hood User Manual


 
Reprogramming the timers
The grease filter timer is preset to 30
hours. This time can be lengthened or
shortened to 20, 30, 40 or 50 hours.
A time of 20 hours should be
programmed in kitchens with
frequent pan or deep frying.
A time of 20 hours should also be
programmed if the kitchen is only
used occasionally. Otherwise grease
which has accumulated over a long
period of time will harden on the
filters making cleaning more difficult.
Reprogramming the grease filter
timer
^ Press the joystick to the left to turn
the fan off.
^
Press the Delayed Shut Down and
the grease filter buttons at the same
time.
The indicator for the grease filter and
one of the fan power scale indicators
will flash.
The indicators of the fan power scale
show the programmed time:
1st indicator from the left = 20 hours
2nd indicator from the left = 30 hours
3rd indicator from the left = 40 hours
4th indicator from the left = 50 hours
^ Use the joystick to select the desired
time. Press it to the left for a shorter
operating time, to the right for a
longer operating time.
^
Store the selection by pressing the
grease filter button.
All indicators will go out.
If the procedure is not stored within 4
minutes of programming the hood will
automatically default to the “old” data.
Operation