Miele DA 229-2 Ventilation Hood User Manual


 
a 2 protective shields
prevent scratches to the chimney dur
-
ing installation.
b 2 hose clips for securing the
ducting.
c 1 reducing collar
for use with 5" (125 mm) exhaust
ducting.
d 1 non-return flap
e Upper retaining plate B secures
the chimney extension.
f Middle retaining plate C for addi
-
tional stability of the chimney.
g Lower retaining plate A secures
the canopy and the motor assembly.
6 screws 5 x 60 mm
10 large headed screws 5 x 40 mm
(S8 wall anchors included in the pack
-
aging are not for use in USA/CDN.)
2 M 6 locking nuts for securing the
motor assembly.
4 screws 3.9 x 7.5 mm for securing the
chimney and the chimney extension.
CAUTION:
During the installation process,
please be careful of sharp edges
that can cause harm.
Installation accessories
23