Miele DA 289-4 Cooktop User Manual


 
The cooker hood works with
. . . air extraction:
The air is drawn in through the vapour
plate, cleaned by the grease filter and
directed outside.
If the on-site ventilation system does
not have a non-return flap, the
non-return flap supplied with the
appliance must be fitted in the exhaust
socket in the motor unit.
Having a non-return flap fitted in the
ducting ensures that air, once ducted
to the outside, cannot get back into the
room again.
The flap is closed when the cooker
hood is switched off.
When the cooker hood is switched on,
the non-return flap opens for the
cooking vapours to be ducted away.
...anexternal fan:
( ...EXT models only)
The ...EXT models are designed to be
connected to an external fan located
outside the room.
The external motor is connected to the
cooker hood by means of a control
cable, and is operated by the controls
on the cooker hood.
Modes of operation
11