Miele DA 3590 Cooktop User Manual


 
,
Before installation, it is important
to read the information given on the
following pages as well as the
Warning and Safety instructions at
the beginning of this booklet.
This is particularly crucial when
using the cooker hood at the same
time as a heating appliance that
relies on oxygen from the same
room, which could result in the
build-up of toxic fumes.
Repositioning the venting
connection
The motor unit can be rotated to allow
the vent ducting to be fitted at the back
of the cooker hood.
This may be necessary if the cooker
hood is being fitted in a reduced height
wall unit, for example.
Repositioning is carried out before
installing the cooker hood.
,
The cooker hood must be
disconnected from the mains
electricity supply.
^
Undo the fixing screws on the front
panel of the cooker hood housing
and remove the panel.
^
Undo the screws on the cover on the
back of the cooker hood housing and
remove the cover.
^
Unscrew the fixing screws on the
motor unit.
^
Turn the motor unit towards the rear
and position the exhaust socket in
the exhaust vent on the back panel of
the cooker hood housing. Ensure
when turning the motor unit that the
connection cable does not become
detached.
^
Secure the motor unit in its new
position.
^
Now secure the cover taken from the
back panel to the top of the housing.
^
Refit the front panel and secure it
using the screws.
EXT models
On appliances with an external motor
(EXT models), the exhaust socket (not
the motor unit) needs to be
repositioned.
^ Unscrew the fixing screws and pull
the top and bottom sections of the
socket apart.
^
Position the top section of the socket
over the exhaust vent on the back
panel of the cooker hood housing
and attach the bottom section to it
from inside. Secure the exhaust
socket with the fixing screws.
Installation
28