44
Technical data
G 7883, G 7893, G 7883 CD
Washer-disinfectors G 7883 G 7893 G 7883 CD
Frontloading unit with bottom-hinged door, excl. baskets • • •
Freestanding unit with lid, can be built under • • –
Built-under/freestanding unit with lid – – •
Freshwater system, max. temperature 93°C • • •
Circulation pump [Qmax. l/min] 400 400 400
Controls/programmes
MULTITRONIC Novo plus/10 programmes • • •
Electric door lock • • •
Buzzer, acoustic signal at end of programme • • •
Programme continuation in event of power outage • • •
Serial interface for process documentation (SST) • (depending on model) • (depending on model) •
Water supply connection
1 x cold water, 0.5–10 bar flow pressure (50–1000 kPa) • • •
1 x cold water for steam condenser, 0.5–10 bar flow pressure (50–1000 kPa) – – •
1 x demineralised water, 0.5-10 bar flow pressure (50–1000 kPa) • (only units without ADP) • (only units without ADP) • (only units without ADP)
1 x hot water, 0.5-10 bar flow pressure (50–1000 kPa) • • •
No. of inlet hoses
1
/
2
" with
3
/
4
" threaded union, length approx. 1.7 m 3 3 4
Drain pump DN 22, head height 100 cm • • •
Steam condenser water drain (DN 22) – – •
Waterproof system (WPS) • • •
Electrical connection, supply lead approx. 1.7 m, 5 x 2.5 mm
2
3 N AC 400 V 50 Hz • • •
Heating [kW] 9.0 9.0 9.0
Circulation pump [kW] 0.7 0.7 0.7
Total rated load [kW] 9.7 9.7 9.7
Fuse rating [A] 3 x 16 3 x 16 3 x 16
Electrical connection for UK only
1 N AC 230 V 50 Hz, connection cable ca. 1.7 m, 3 x 4.0 mm
2
•••
Heater rating [kW] 6 6 6
Circulation pump [kW] 0.7 0.7 0.7
Total connected load [kW] 6.7 6.7 6.7
Fuse rating [A] 30 30 30
3 N AC 400 V 50 Hz, connection cable ca. 1.7 m, 5 x 2.5 mm
2
•••
Heater rating [kW] 8.5 8.5 8.5
Circulation pump [kW] 0.7 0.7 0.7
Total connected load [kW] 9.2 9.2 9.2
Fuse rating [A] 3 x 16 3 x 16 3 x 16
Connection options
DOS K 60 or DOS K 60/1 for liquid detergents/chemicals 1 1 –
G 7883/G 7893