Miele H 187 MB Microwave Oven User Manual


 
All electrical work should be carried out
by a suitably qualified and competent
service technician approved by Miele in
strict accordance with national and lo
-
cal safety regulations.
Depending on the version, the appli
-
ance is supplied with a mains cable, or
a mains cable and plug for connection
to a.c. 50 Hz, 230 - 240 V single phase
supply.
The voltage, rated load and fuse rating
are given on the data plate situated at
the front of the oven interior. Please en
-
sure that these match the household
mains supply.
Connection should be made via a fused
connection unit or a fused plug and a
suitable switched socket, (rated load
under 3000 W), or via a suitable isolator
(rated load over 3000 W), which com-
plies with national and local safety reg-
ulations, and the on/off switch should
be easily accessible after the appliance
has been installed.
If the socket is not accessible after in
-
stallation (depending on country) an
additional means of disconnection must
be provided for all poles.
When switched off there must be an all-
pole gap of 3 mm in the isolator switch
(including switch, fuses and relays acc.
to EN 60335).
For extra safety it is advisable to install
a residual current device with a trip cur
-
rent of 30 mA (in accordance with DIN
VDE 0664, VDE 0100 Section 739).
If the cable is damaged a new cable
must be fitted by a Miele approved ser
-
vice engineer.
In certain unfavourable circumstances
microwave appliances can be a source
of interference. In this event please
contact your dealer or the Miele Service
Dept.
If the appliance is connected via an iso
-
lator switch the plug must be cut off
and rendered useless.
Important U.K.
The wires in the mains lead of this ap
-
pliance are coloured in accordance
with the following code:
Green/yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the markings identifying the
terminals in your plug, proceed as fol-
lows:
The wire coloured green and yellow
must be connected to the terminal in
the plug which is marked with the letter
E or by the earth symbol z or coloured
green or green and yellow.
The wire coloured blue must be con
-
nected to the terminal marked with the
letter "N" or coloured black. The wire
coloured brown must be connected to
the terminal marked with the letter "L" or
coloured red (U.K).
WARNING
THIS APPLIANCE MUST BE
EARTHED
Electrical connection IRL, U.K., ZA