Miele KT 12410 S Refrigerator User Manual


 
a Top box
b Appliance
c Housing unit
d Wall
The appliance can be installed in a
kitchen run. To match the height of the
rest of the kitchen, the appliance can
be fitted with a suitable top box a.
A ventilation gap of at least 50 mm
depth must be allowed for behind the
appliance for air to circulate.
The cross section of the air outlet under
the room ceiling must be at least 300
cm
2
to ensure that air can circulate
without hindrance. Otherwise the
appliance has to work harder, resulting
in an increase in electricity
consumption.
The air inlet and outlet must not be
covered or blocked in any way.
They should be dusted on a regular
basis.
When installed next to a wall d a
distance of approx. 30 mm is needed
on the hinge side between the wall d
and the appliance b, so that the doors
have sufficient space for opening.
When securing to adjoining furniture or
if a spacer is fitted between the
appliance and the wall, please note the
following:
^ Check that the doors can be opened.
^ Do not drill within the greyed out
area (see diagram) as this would
damage insulated parts of the
appliance.
^ Secure the appliance to the adjoining
kitchen furniture unit using
self-tapping screws. The maximum
depth you can screw into the
refrigerator is 10 mm. Do not exceed
this amount.
Building in the appliance
42