7
Important safety requirements
This hob must be installed in accordance with
the IEE Wiring Regulations (Current Edition).
Detailed recommendations are contained in
the following British Standards Codes Of
Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S.
6891 Current Editions.
Location
This hob has been registered as a "Class
X" appliance according to Fire Risk
Regulations.
Minimum distances detailed below must be
observed. The hob may be located in a
kitchen, a kitchen/diner or bed sitting room,
but not in a bathroom or shower room.
Before making the cut out in the worktop
ensure that there is a minimum distance of 55
mm. between the rear edge of the hob and
the wall. A minimum distance of 100 mm. must
be left between the side edges of the hob and
any adjacent cabinets or walls.
The minimum distance combustible material
can be fitted above the hob in line with the
edges of the hob is 400 mm. If it is fitted below
400 mm. a space of 50 mm. must be allowed
from the edges of the hob.
The minimum distance combustible material
can be fitted directly above the hob is 700 mm.
650 mm
400 mm
400 mm
100 mm
50 mm
50 mm
55 mm
600 mm
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE HOB
WITH A COOKER HOOD ABOVE
FO 0813
650mm
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE HOB
WITHOUT A COOKER HOOD ABOVE
FO 0812