Moffat MUL 514 Refrigerator User Manual


 
9
Fault code / malfunction Solution
Something not working
The light does not come on
Check there is power at the socket.
Check there is not a power cut by checking the household lights.
Check the fuse has not blown.
Ensure that the bulb is correctly fitted.
Replace the bulb if it has blown.
Check the door light switch is not jammed.
The compressor runs
continuously
Check the ambient temperature is within the appliances
operating limits of 10°C to 38°C.
Check the thermostat control knob is turned to the correct setting
relative to ambient conditions.
Adjust the thermostat control knob to give correct
temperature control. See page 5.
Check that the door is closed.
Large quantities of food have recently been placed in
the cabinet and/or door is frequently opened.
Check that air ventilation is not obstructed.
IMPORTANT!
Before contacting your local Service Force Centre check the following points.
IMPORTANT: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect
use or installation, a charge will be made even if the appliance is under guarantee.
If after the above checks, there is still a fault, call your local Service Force Centre.
In-guarantee customers should ensure that the above checks have been made as the engineer will
make a charge if the fault is not a mechanical or electrical breakdown.
Please note that proof of purchase is required for any in-guarantee service calls.
IMPORTANT!
When carrying out the suggested corrective
actions the appliance must be switched off.
No power to appliance
The temperature in the fridge or
freezer section is too high
Excessive frost and ice has built
up.
Ensure the door is not left open.
Check that nothing is preventing the door from closing. Is the
door gasket intact and clean?
Noise
Refer to normal operating sounds.
Water under the salad bins
Check the drain hole is not blocked.
(see Maintenance and Cleaning).
2222685-50.qxd 14/04/2006 13.47 Pagina 9