Monessen Hearth VFCS20DNV Oven User Manual


 
58D6002 15
ON
OFF
CHECKING GAS PRESSURE and CONNECTING REMOTE RECEIVER
MILLIVOLT CONTROL (FIGURE 11)
Thevalveregulatorcontrolstheburnerpressurewhichshould
becheckedatthepressuretestpoint.
Ifoutletpressureislow,checkinletpressureagainstdataplates
or manual.
Turncapturedslottedscrewcounterclockwise2or3turnsand
thenplacetubingtopressuregaugeovertestpoint(Usetest
point“OUT”closestto controlknob).Aftertakingpressure
reading,besureandturncapturedscrewclockwisermlyto
re-seal.Donotovertorque.Checkforgasleaks.
NOTE: Remove control panel to access gas valve.
Figure 11 - Pressure Test Point Location
Milli-Volt Control
Test Port “OUT”
CONNECTING REMOTE RECEIVER
1. Removecoveroncontrolpaneltoshowopeningfor
remote receiver. See Figure 12.
2. FollowremotereceiverInstructionstomakeallneces-
sarywiringconnections.
3. Placeremotereceiverintheopeningofcontrolpanel.
Use two screws provided to attach remote receiver to
the control panel. See Figure 12.
Figure 12 - Installing Remote Receiver
Remote Receiver
Cover
NOTE: Do not place remote in combustion chamber.
Theheatergasinletconnectionis3/8"NPTatthevalve.The
inletislocatedonleftsideofstove.Removefrontcontrol
plate to better access the inlet.
Whentighteningupthejointtothevalve,holdthevalvesecurely
with a wrench to prevent movement.
Testallgasjointsfromthegasmetertotheheatervalvefor
leaksusingagasanalyzerorsoapandwatersolutionaftercompletingconnection. DO NOT USE AN OPEN FLAME.
CheckthegaspressurewiththeapplianceburningandthecontrolsettoHIGH.
WARNING
Connecting directly to an unregulated
propane/L.P.G. tank can cause an
explosion.