IMPORTANT SAFETY INFORMATION
Continued from page 3
16. Keep room area clear and free from combustible materi-
als,gasolineandotherammablevaporsandliquids.
17. Unventedgasheatersareasupplementalzoneheater.
They are notintended tobe a primaryheating appli-
ance.
18. Unventedgasheatersemitmoistureintothelivingarea.
Inmosthomesofaverageconstruction,thisdoesnotpose
aproblem.Inhousesofextremelytight construction,
addition mechanical ventilation is recommended.
19. Duringmanufacturing,fabricatingandshipping,various
components of this appliance are treated with certain
oils,lmsorbondingagents.Thesechemicalsarenot
harmfulbutmayproduceannoyingsmokeandsmells
astheyareburnedoffduringtheinitialoperationofthe
appliance;possibly causingheadachesor eye or lung
irritation. This is a normal and temporary occurrence.
Theinitialbreak-inoperationshouldlasttwotothree
hours with the burner at the highest setting. Provide
maximumventilationbyopeningwindowsordoorsto
allowodorstodissipate.Anyodorsremainingafterthis
initialbreak-inperiodwillbeslightandwilldisappear
with continued use.
20. Inputratings are shown in BTU per hour and are for
elevationsupto2,000feet.Forelevationsabove2,000
feet,inputratingsshouldbereduced4percentforeach
1,000feetabovesealevel.RefertotheNationalFuel
Gas Code.
21. Theapplianceanditsappliancemaingasvalvemustbe
disconnectedfromthegassupplypipingsystemduring
anypressuretestingofthatsystemattestpressuresin
excessof1/2psig(3.5kPa).
22. The appliance must be isolated from the gas supply
piping system byclosing itsequipment shutoff valve
during any pressure testing of the gas supply piping
systemattestpressuresequaltoorlessthan1/2psig
(3.5kPa).
23. Do not use this room heater if any part has been under
water.Immediately call a qualied service technician
to inspect the room heater and to replace any part of the
controlsystemandanygascontrolwhichhasbeenunder
water.
24. Neverburnsolidfuelsinanunventedroomheater,re-
place or stove.
25. Do not set kettles or humidifying devices on top of
stove.
26. Thestovedoor/screenmustbeclosedwhentheappli-
anceisoperating.Thescreenshall haveopenings for
induction of combustion air.