58D6002 29
Note: All troubleshooting items are listed in order of operation.
TROUBLESHOOTING
WARNING
WARNING
Turn appliance OFF and allow to cool
before servicing. Only a qualified
service person should service and
repair the heater.
SYMPTOM POSSIBLE CAUSE ACTION
When ignitor
button is
pressed, there
is no spark at
ODS/pilot.
1.Ignitor electrode positioned
wrong.
1 Replaceignitor.
2.Ignitorelectrodeisbroken. 2. Replaceignitor.
3.Ignitorelectrodenotconnected
toignitorcable.
3. Reconnectignitorcable.
4. Ignitor cable pinched or wet.
Keepignitorcabledry.
4. Freeignitorcableifpinchedbyanymetalortubing.
5.Brokenignitorcable. 5. Replaceignitorcable.
6.Badpiezoignitor. 6. Replacepiezoignitor.
Appliance
produces
unwanted
odors.
1.Applianceburningvaporsfrom
paint,hairspray,glues,etc.
1. Ventilateroom.Stopusingodorcausingproductswhileheaterisrunning.
2.Gasleak 2. Locateandcorrectallleaks.
3. Initial burn off. 3. Ventilateroomandturnunitonhighuntilodorisgone.Odorshouldbegone
after 2 to 3 hours of continuous use.
Appliance
shuts off
during use.
1. Notenoughfreshairisavailable
forODS/pilottooperate.
1. Openwindowand/ordoorforventilation.
2. Lowlinepressure. 2. Contactlocalgascompany.
3. ODS/pilotispartiallyclogged. 3. CleanODS/pilot.
4. Defective Thermopile.
4. Checkpilotame.Checkwireconnections.Checkthermopileoutput—should
be500milli-voltsacrossTH/TPandTPTerminalswithON/OFFswitchoff.
5. Restrictions in incoming air
ow.
5. Check forobstructions on bottom of unit. Check for improper logplace-
ment.
Gas odor even
when control
knob is in OFF
position.
1. Gasleak. 1. Locateandcorrectallleaks.
2. Control valve defective. 2. Replacecontrolvalve.
When ignitor
button is
pressed, there
is spark at
ODS pilot, but
no ignition.
1. Gas supply turned off or appli-
ance shutoff valve closed.
1. Turnongassupplyoropenmanualshutoffvalve.
2. Airingaslineswheninstalled. 2. Continueholdingdowncontrolknob.Repeatignitingoperationuntilairis
removed.
3. ODS/pilotisclogged. 3. ReplaceODS/pilotassemblyorgetitserviced.
4. Gasregulatorsettingisnotcor-
rect(LPG).
4. Replacegasregulatorattank.