PRODUCT SPECIFICATIONS
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
1
/2" w.c. on Natural Gas
systems operating at higher pressure.
MILLIVOLT PRESSURE
RegulatorPressureSetting: 3.5"w.c.
PilotRegulator: 3.5"w.c.
GasInletPressure: Max.101/2"w.c. Min.5"w.c.
IGNITION CONTROLS
Piezoignitorallowsignitionofthepilotwithouttheuseofmatches.
Milli-Volt control has four (4) positions:
OFF - Allgastotheburnerisshutoffatthevalve.
IGN - Valvepositiontolight/maintainastandingpilot.
ON - ValvepositiontoturnburnersON/OFFwithremoteswitch.
LOW/HI - Variablepositiontocontrolameheight(heatoutput).Bothfrontandrearburnersareinoperationto
providerealisticglowandyellowame.
PILOT/ODS
Thegaslogheateristtedwithaspeciallydesignedsafetypilot(ODSassembly)lightwhichsensestheamountofoxygen
availableintheroomandshutsthegaslogheateroffiftheoxygenlevelbeginstodropbelowasatisfactorylevel.Thepilot
can only be relit when adequate fresh air is available.
THERMAL GENERATOR
Themillivoltgaslogpilotisttedwithamillivoltthermopilegeneratortoprovidepowerforremoteactivation.
PROPANE / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLIVOLT PRESSURE
RegulatorPressureSetting: 10"w.c.
GasInletPressure: Maximum13"w.c.
Minimum11"w.c.
Model Number Type
Gas Rate
Max. BTU/Hr Min. BTU/Hr
CSVF20SNV/VFCS20DNV (G-EBL-ES-EMB)
CSVF30SNV/VFCS30DNV (G-EBL-ES-EMB)
Milli-Volt
Milli-Volt
10,000
32,000
6,000
20,000
Model Number Type
Gas Rate
Max. BTU/Hr Min. BTU/Hr
CSVF20SPV/VFCS20DPV (G-EBL-ES-EMB)
CSVF30SPV/VFCS30DPV (G-EBL-ES-EMB)
Milli-Volt
Milli-Volt
10,000
32,000
6,000
20,000