Moyer Diebel DF-M6 Dishwasher User Manual


 
INSTALLATION (Cont’d)
Electrical Connections
1. The Glass Washer has a six foot power cord with a “U” ground tandem plug for connection
to a power receptacle.
2. Provide a nonlocking 250 volt, 15 ampere, 2 pole, 3 wire grounding receptacle within four
feet of the base of the Glass Washer(CSA TYPE 6-15R). This should be installed by a
qualified electrician to meet the specifications of the local electrical code.
3. This machine operates from 208 to 240 volts.
NOTE:
This machine is 50Hz and 60Hz compatible.
Plumbing Connections
Hot Water Connection
1. Connect a minimum 1/2" water line to the hot water solenoid valve. Supply temperature
must be minimun 140°F/60°C, with a flow pressure between 25-95 PSI/172-656 kPa.
2. Hot water consumption is approximately 10 Imp. gph./12 U.S. gph/45 litres/h.
Cold Water Connection
1. Connect a minimum 1/2" water line to the cold water solenoid valve. Flow pressure must
be between 25-95 PSI/172-656 kPa.
2. Open mixing valve located between hot and cold solenoid valves for areas with very cold
rinse water to heat the rinse water which will prevent glasses from cracking.
3. Cold water consumption is approximately 2.4 Imp. gpm/2.8 U.S. gpm/10.6 litres/min.
NOTE:
Install check valves on the hot and cold water lines as close as possible to the water inlet.
Drain Connection
1. This machine is gravity drain. Connect a 1-1/2" drain line where indicated.
2. PVC pipe is generally recommended as copper is prone to attack by the sanitizing
chemicals.
WARNING:
Plumbing and electrical connections should be made by a qualified workman who will
observe all the applicable plumbing, sanitary and safety codes. Before all utilities are
installed, ensure that all the bullet feet are in contact with the floor and at the desired
level.
8
INSTALLATION
!