6
1. Locate the built-in stainless steel booster on the left-side of the dishwasher.
2. Connect a 3/4” NPT hot water supply to the dishwasher at the line strainer.
Installation Guide _____________
; Water Connection MD-1000HT
Dishwasher temperature
and water pressure requirements:
140°F/60°C minimum) for 40° F/22° C rise booster
(35 psi/241 KPa static pressure)
7-10 p
si/63-69Kpa flow pressure
(110°F/43°C minimum) for 70° F/39° C rise booster
(35 psi/241 KPa static pressure)
7-10 p
si/48-69Kpa flow pressure
Note:
The existing hot water supply lines to the dishwasher must be 3/4" NPT or larger. To the best of
your ability inspect, and verify that all supply piping meets the 3/4" NPT requirement.
MD-1000HT • Water Connection
Note:
The following components are not required for proper dishwasher operation, but are
highly recommended, because they make servicing of the dishwasher much faster.
Install the following components (not supplied) in the hot water supply line:
1) 3/4” or larger water shut-off valve near the machine in the water supply line.
2) ASSE 1010 Water hammer arrestor upstream from the shut-off valve.
3) Pressure gauge 0-60 PSI minimum downstream from the PRV.
4) Temperature gauge 0-180°F/82°C (not supplied) downstream from the gauge.
Note:
The installing plumber must connect a water supply line to the dishwasher that is equal to or
greater than 3/4" NPT in size and a 3/4" pressure regulating valve, PRV (not supplied).