Multiquip MQ62TDD Trash Compactor User Manual


 
PAGE 30 — MQ62TDD TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #0 (07/30/09)
2. Remove oil filter cannister from engine by turning
cannister counterclockwise.
3. Lubricate oil filter gasket with a small amout of oil.
Reinstall oil filter by rotating cannister clockwise. DO
NOT over-tighten.
Battery Maintenance
Mishandling of the battery shortens the service life of the
battery and adds to maintenance cost. When handling the
battery do the following:
Be careful not to let the battery electrolyte come in contact
with your body or clothing.
ALWAYS wear
eye protection
and
rubber gloves
, since
the battery contains sulfuric acid which burns skin and
eats through clothing.
ALWAYS check the battery terminals periodically to
ensure that they are in good condition.
Use wire brush or sand paper to clean the battery
terminals.
ALWAYS check battery for cracks or any other damage.
If white pattern appears inside the battery or paste has
accumulated at the bottom, replace the battery.
If the pump will not be in operation for a long period of
time, store in cool dry place and check the battery charge
level every month to maintain the performance of the
battery.
MAINTENANCE (ENGINE)
CAUTION — Battery Hazards
Wear
safety glasses
or
face mask
,
protective clothes, and rubber gloves
when working with battery.
BATTERY ELECTROLYTE
LEVEL
BATTERY ELECTROLYTE
LEVEL
TOO
LOW
TOO
LOW
NORMAL
TOO
HIGH
TOO
HIGH
VENT WELL
Figure 21. Battery Electrolyte Levels
If the battery cables are connected
incorrectly, electrical damage to the
alternator, engine control box and other
electrical componets may result. Pay close
attention to the polarity of the battery when
connecting the battery cables.
Check the battery regularly and make sure that each
electrolyte level is to the bottom of the vent well
(Figure 21). If necessary add only distilled water in a
well-ventilated area.
ALWAYS place a small amount of battery terminal
treatment compound around both battery terminals. This
will ensure a good connection and will help prevent
corrosion around the battery terminals.
Inadequate battery connections may cause poor starting
of the generator, and create other malfunctions.