13
W415-0158 / E / 02.19.04
Ensure that 2 female ends remain at the top.
Re-secure the access plate.
3. Remove the spill switch bracket from the rear of the
adapter. Unscrew the spill switch and discard the bracket.
Attach the spill switch to the bracket supplied with the stove
and secure onto the adapter.
4. Bring the wires through the lower hole in the adapter. To
pass the wires through the hole more easily, temporarily
tape the two terminals together.
5. With the spill switch opening aligned to the back of the
stove, take hold of the adapter base and push the crimped
edge into the stove flue collar.
6. Connect the upper wire terminals to the spill switch.
7. Disconnect the wire lead from terminal 3 on the valve
and reconnect to the male end of the spill switch wire. Con-
nect the female end of the spill switch wire to terminal 3 on
the valve.
Leave all excess wire in an orderly manner.
For aesthetics, the adapter has been designed to ac-
cept a standard matte black 7" stove pipe and the Na-
poleon decorative brass band (standard with the
GS-150KT). Both are available from your Napoleon
dealer.
Attach the B-Vent label, shown below, in the control area
of the appliance.
A chimney venting this stove shall not vent any solid fuel
burning appliance.
Any stove needs air for safe operation and must be in-
stalled in such a way that adequate combustion air is
available.
THREE TYPES OF
CHIMNEY SYSTEMS
MAY BE USED WITH
THIS STOVE:
FIGURES 29
FIGURE 31
Follow the instructions of the 'B' vent manufacturer for chim-
ney installation.
1. Remove the access plate. Remove and discard the air
intake cover plate located directly behind the access plate.
2. Feed the 2 wires, supplied, through the 7" collar at the
top of the unit; bring them out the air intake opening but
behind the rear panel as shown.
FIGURE 30
ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE.
THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.
ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.
CE FOYER A ETE CONVERTI A UN MODELE A SYSTEME D’EVACUATION ‘B’.
ws-385-160
B-VENT SPECIFICS - MODEL GS60
CHIMNEY INSTALLATION
COMBUSTION AIR
INSTALLING 'B' VENT:
B-VENT MODEL GS60 ONLY