R E P A I R S
8.6.5 Removingcoreunits
• Foreachcoreunitloosen1remainingscrew(41,ovalshapedhead)atthebottom
sideofplatform.
Forcompleteremovalofacoreunitproceedasfollows:
4. Disconnect2insulatedadapterplugs(15,phaseandneutralwire).
5. Ifagroundwire(15,partofthermoblock)ispresent,disconnectflatreceptacle.
6. Openprotectivecase(69)withscrewdriveranddisconnectconnectioncable(b).
7. Pulloutcoreunitfromplatformslightlytodisconnectsynchronizationcableplug(a)
fromelectroniccontrolboard.
8. PulloffbothhosesfromangledHconnector(65).
9. Liftcoreunitoutofplatform.
Bothcoreunitscan
beremovedthesame
way.
Afterthefirstrepair
stepthecoreunitcan
bepulledoutofthe
platformslightly(withstill
connectedhosesand
wires).Nowthecoversof
thecoreunitcanbe
removed.
Theflatreceptacleon
thegroundwirehasa
specialconnector
latching(seedetail).Press
downleveratfirst,thenpull
offreceptacle.