Lifebreath RNC120F Ventilation Hood User Manual


 
17
Ventilation Dehumidistat
PART NO. 99-116
The High/Low Speed Switch initiates High or Low speed ventila-
tion. This control also has an ON/OFF Switch and a
Dehumidistat Dial (refer to "The ON/OFF Switch" and "The
Dehumidistat Dial" descriptions).
Remote Dehumidistat
PART NO. 99-130 White
The Remote Dehumidistat activates high speed ventilation when
the indoor humidity level exceeds the set point.
Remote Control Devices
20 Minute Timer
PART NO. 99-132
Connects to RED, BLACK and GREEN
(LED drive) terminals. Use a minimum of
three 20 gauge low voltage wire. Connect
up to 4 on 100 ft (91 m) wire max. Mounts
ina2x4box.
DEHUMIDISTAT
Off
10
20
30
40
50
60
Optional Main Controls
The amount of ventilation required in your home will fluctuate
according to the activity level in the house. Higher activity levels
require more ventilation.
Main controls can be mounted in a central location of the home
(i.e. beside the furnace thermostat) which will provide the user
with complete control over their ventilation system from a conve-
nient location.
The ON/OFF Switch
The ON/OFF Switch will turn the HRV ON or OFF. Controls with
an ON/OFF switch can be modified to ON/Standby by adjusting
the circuit board DIP Switches (Refer to "Mode DIP Switch
Settings").
The Dehumidstat Dial
Main controls feature a dehumidistat dial. The dehumidistat is
used to reduce high winter humidity levels. The dehumidistat
activates high speed ventilation when the indoor humidity level
exceeds selected setting.
Optional Timers
Timers should be present when the HRV is exhausting from
specific locations i.e bathrooms, laundry rooms. The 20 Minute
Timer is the best selection, however, the crank timer will be nec-
essary if only 2 lead low voltage wires are present.
Only one main control can be installed on your
system.
ATTENTION
Dehumidistat
Dial
High/Low
Speed Switch
ON/OFF
Switch
Crank Dial
Rotate the dial for up to 60
minutes high speed opera-
tion.
20/40 ON/OFF Dehumidistat
PART NO. 99-2040
The 20/40 Switch will toggle from continuous low speed ventila-
tion to an intermittent mode of 20 minutes fan ON (in low speed)
and 40 minutes fan OFF. The Dehumidistat Dial will initiate High
Speed ventilation when the indoor humidity level exceeds the set
point (regardless position of the 20/40 Switch.). This control also
has an ON/OFF Switch (refer to "The ON/OFF Switch" descrip-
tion).
Dehumidistat
Dial
20/40
Switch
ON/OFF
Switch
Dehumidistat
Dial
Crank Timer
PART NO. 99-101
Connects to RED and BLACK termi-
nals. Use a two 18 gauge low
voltage wire. Mounts ina2x4box.
The crank timer provides a solution
to installing a system where only 2
wires are present for the timers.
20 Minute Status Lights
The 20 Minute Status Light indicates
high speed operation is activated.
Touch Pad
The Touch Pad initi-
ates high speed
operation.