Lifebreath RNC120F Ventilation Hood User Manual


 
18
Wiring the Controls
Red to Red
Black to
Black
Green LED
Drive to Green
DEHUMIDISTAT
Red to Red
Orange to
Orange
Black to
Black
Dehumidistat Ventilation Control
Part No. 99-116
20 Minute Timer
(shown in a Decora cover plate)*
Red to Red
Black to Black
Remote Dehumidistat
Part No. 99-130W
Remove
factory
installed
jumper when
installing this
control
Factory
installed
jumper
Factory
installed
jumper
Circuit Board
Terminal Strip
Circuit Board
Circuit Board
Terminal Strip
Red to Red
Black to
Black
Red to Red
Orange to
Orange
Black to Black
2040 ON/OFF Dehumidistat
Part No. 99-2040
Crank Timer
Part No. 99-101
Red to Red
Black to Black
Recirculation Control
Part No. 99-RECIRC
Remove
factory
installed
jumper when
installing this
control
Remove
factory
installed
jumper when
installing
this control
Factory
installed
jumper
Circuit Board
Terminal Strip
Circuit Board
Terminal Strip
Circuit Board
Terminal Strip
Low Fan
to Blue
Orange to
Orange
Recirculate
to Blue
Off
10
20
30
40
50
60
ATTENTION
Controls will use 2, 3 or 4 lead 20 gauge wire. Note
the number of leads required for each control (refer
to the above illustrations).