NuTone NP60000 Ventilation Hood User Manual


 
- 9 -
9. INSTALL THE ROUGH-IN PLATE TO THE HOOD (ALL BLOWERS)
Run power cable to installation location. Refer to the instructions included
with the selected blower or rough-in kit (sold separately) for details on
installing the rough-in plate. Install the rough-in plate so that the wiring
box is located on the right side as you are facing the hood.
For ducting through back of hood, remove existing plate from inside
back of hood and attach it to inside top of hood to cover hole. Secure to
threaded studs with same (4) nuts.
For ducting through top of hood, existing plate remains in place on
inside back of hood.
Connect ducting to transition or rough-in plate as you are installing the
rough-in plate. Use duct tape to make all joints secure and air-tight.
10. CONNECT THE WIRING (ALL BLOWERS)
Remove wiring cover from rough-in plate and set aside.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Reinstall wiring cover.
HD0063
1
1
1
1
2
3
4
1. Locknuts 3. Rough-in plate on back of hood
2. Plate on top of hood 4. Wiring cover
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power to be switched on accidentally.
!
11. INSTALL THE OPTIONAL SOFFIT CHIMNEY
(OPTIONAL)
RMN Series
Refer to the instructions included with the soffit chimney.
12. INSTALL THE BLOWER (INTERIOR OR EXTERIOR BLOWER)
Refer to instructions included with blower.
Once the blower is installed, plug the power supply to the 3-prong male
connector (A) and the blower unit into the 2-prong female receptacle (B)
inside the hood.
HE0003
WARNING
Never plug the 2-prong blower cord to the 3-prong power
supply cord.
!
A
B