Chemical Injector Pump and Solution Tank Installation
Figure 7
Chemical Injector Pump Installation
!IMPORTANT!
Install the Chemical Injector Pump into the water supply after the Pre-Filter and before any other filtration
or softening system.
1. Determine the size and material of your incoming water supply line from the Pre-Filter System.
2. Mount the Chemical Injector Pump to the wall using the provided brackets. Line up the inflow and
outflow connections with the current water line.
3. Plumb the Chemical Injector Pump into your water line. The arrow on the body of the Chemical
Injector Pump shows the correct water flow direction. The water should enter and exit the pump
following the direction of the arrow.
Solution Tank Installation
1. Remove the black cap from the opening on the Solution Tank.
2. Drill one 3/8” hole into the top of the Solution Tank.
3. Insert the end of the Chemical Injector Pump Tubing with the pump foot valve connected, into the
hole which was covered by the black cap on the top of the Solution Tank.
4. Feed and pull the other end of the tubing through the drilled opening on the top of the Solution
Tank.
5. Fill the Solution Tank with 9 cups household bleach and 35 gallons of fresh bottled water. Replace
the cap.
6. Determine the length of Chemical Injector Pump Tubing required to reach the bottom connection
point of the Chemical Injector Pump and then cut the Chemical Injector Pump Tubing to the
appropriate length.
7. Connect the Chemical Injector Pump Tubing to the suction valve on the Chemical Injector Pump.
!IMPORTANT!
Ensure the Chemical Injector Pump Tubing is free of kinks.
!IMPORTANT!
Ensure Solution Tank is not sitting directly on a concrete floor.
Incoming
Water
Supply
Outgoing Water
to House
35 Gallon
Solution Tank
Pump Foot
Valve
Chemical Injector
Pump Tubing
Chemical Injector
Pump
Nut
Pre-Filter
Spigot
(optional)