Complete the Installation
1. Turn on the main water supply.
2. Check for leaks.
3. Peel off the protective plastic wrap from the stainless steel tank jackets.
4. Add the Pelican logo sticker in the desired location on the tank.
5. Wax stainless steel tank jacket(s) with wax provided or any other non-abrasive auto wax a
minimum of 1-2 times per year or as needed based on the installed environment.
Programming the Electronic Head
Note: Power Source - For safety reasons the outlet must be protected by a Ground Fault Circuit
Interrupter (GFCI).
Note: These settings are specific to this system. Do not make changes to the settings unless instructed by
customer service. All settings have to be set by first setting the clock to 12:01 PM. To restart programming,
you must start over at step 1. Do not go to a previous step, you must start over at step 1.
Figure 10
Step 1: Setting the Valve
1. Press and hold the UP or DOWN button to change the clock to 12:01 PM.
2. Press the EXTRA CYCLE button once.
3. Press and hold the UP and DOWN buttons together, until DF is displayed in the left corner. Scroll
using the UP and DOWN arrows until "GAL" is selected. Press EXTRA CYCLE.
Extra Cycle
Button
Up
Button
Down
Button