Preventative Maintenance
ArcticCold Draft Dispenser
Cleaning the Condenser
The condensing coil should be inspected before
each operation and cleaned if necessary. The
condensing coil can be accessed by removing the
louvered cover located on the customer side of the
cabinet. The coil can be adequately cleaned with
a vacuum, stiff bristled brush, or forced air. Please
use care to ensure that the fins of the condenser
are not bent or damaged.
Glycol Level
The glycol system should be checked before each
operation to ensure an adequate level. The glycol
reservoir can be accessed by removing the lou-
vered cover on the refrigeration deck. The reservoir
is located at the right rear of the deck, (see figure
A). Remove the sponge insulation and unscrew the
cover. While using a mirror, ensure the glycol level
is at the visible seam inside the reservoir located
approximately 2" below the threads. Contact the
Perlick Corporation for proper glycol solution if
needed.
Pump Motors
Sleeve-bearing pump motors should be oiled at
least once per year, (see figure A).
Casters
The casters should be greased at least once every
6 months. This may be required more often if the
unit is used in dusty environments. There is a
grease fitting located on each caster.