Tools Required
Tape Measure.
Chalk Line.
Caulking Gun.
Caulk (provided).
Clam Lock Wrench (provided).
Level.
Screw Driver.
Shims.
Pre-Assembly
Some panels have been protected with a strip-
pable film to prevent surface damage. Remove this
film before assembly. It is very difficult to remove it
from the panel edges after panels have been joined
together. Note: Do not store panels with protective
film in sunlight or high temperature areas for an
extended period of time.
Placing the Utility Cooler
This utility cooler should not be installed tight
against any building or adjacent cooler wall. A
minimum of two inches must be provided for air
circulation. Shims for leveling the floor must
also be incorporated into overall height and
clearance requirements.
Remote Units: A minimum four inch clearance is
required between the top of the utility cooler
and the ceiling of the building in which it is being
installed.
Self-contained Units: Sufficient clearance above the
cooler must be allowed for ceiling panel
and condensing unit installation. For ventilation
requirements, see page 7.
The Cam Lock Fastening Method
This utility cooler utilizes the cam-lock fastening
method. (See illustration on below.)
Insert the cam lock wrench into the lock before the
panels are pushed together. Turn the handle Cam
Hole counterclockwise as far as it will go to fully
cock the
cam. Note: The cam must be fully cocked to
assure proper locking. The panels should then be
pushed together tightly and locked by turning the
wrench clockwise.
Plugs are provided to insert in cam-lock holes after
final assembly.
3
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2026
Rev 01.28.09
Preparing the Cabinet for Use
CAM
CAM
HOLE
MODEL NOS. US4KP US4KP
KEG CAPACITY
4 10
DIMENSIONS
EXTERIOR
(mm)
Length 47" (1194) 93" (2362)
Depth 47" (1194) 47" (1194)
Height 77" (1956) 79" (2007)
CONDENSING UNIT
1
/
3
1
/
2
FULL LOAD AMPS
8.5 10.2
MAX. FUSE
15 15
SHIPPING WEIGHT
lbs. (kg) 700 (318) 1150 (522)
EXTERIOR Floor: Stucco galvanized steel. Roof, Walls & Doors: Stucco galvanized steel painted grey.
INTERIOR
Floor: 16 gauge slip resistant stainless steell. Roof, Walls & Doors: 26 gauge stucco
galvanized steel.
ELECTRICAL 115 V, 60 Hz. 1ph AC. Junction box provided.
PLUMBING
Evaporator condensate drains through access hole in wall. 20" x
1
/
2
" I.D. drain line provided.
REFRIGERATION R134a refrigerant.
INSULATION 4" UL Class 1 urethane foam. Flame Spreading Rate: 25 or less.
Smoke Develop Rating: 450 or less.
DOORS Flush-mounted with cam-lift chrome hinges, automatic door closer, magnetic gaskets, chrome pull handle. Standard right
hinged. Door size: 30" W x 55" H.
FEATURES Light “ON” indicator in door. Light switch and fixture installed on evaporator. Thermometer furnished loose.
OPTIONAL ACCESSORIES • Foor rack • Keg shelf kit