INSTALLATION
4 L20-293, rev. 0 (1/06)
1) 1” (2.54cm) Access Hole
2) Connection Points
1/2” (1.27cm) Allen Wrench Required
3) Ground Connection
Flat head screwdriver required
1.6. VENTILATION AND FIRE SAFETY SYSTEMS
Your new appliance must have proper ventilation to function safely and properly. It is very important
to install a fire safety system. Your ventilation system should be designed to allow for easy cleaning.
Frequent cleaning and proper maintenance of the ventilation system and the appliance will reduce the
chances of fire. Ventilation and fire safety systems must comply to local and national codes. Refer to
ANSI 83.11 for a list of reference documents that will provide guidance on ventilation and fire safety
systems.
WARNING
DO NOT attempt to connect the appliance to an electrical supply other then that indicated
on the data plate. Electrical connection should be performed by qualified personnel.
WARNING
The electrical connection used by this appliance must comply with local codes. If there are
no local codes that apply, refer to the National Electrical Code (NEC), ANSI/NFPA 70 for
installation in the US. In Canada, refer to CSA Standard C22.2 and local codes. In all other
cases, refer to local and national codes and regulations.
WARNING
The appliance must be grounded in accordance with local code; if there is no local code,
comply with the NEC and ANSI/NFPA No. 70 latest edition (for US and Canadian
installations). In all other cases, refer to local and national codes and regulations. To
comply with European requirements, European models are equipped with an equalization-
bonding clamp. An equalization bonding lead must be connected to this clamp to provide
sufficient protection against potential difference. This clamp, located on the rear of the
appliance is marked with the following universal symbol.
WARNING
This equipment must be installed so that the plug is
accessible unless other means for disconnection
from the power supply (e.g. a circuit breaker) is
provided.
WARNING
If this appliance is permanently connected to fixed
wiring, it must be connected by means of copper
wires having a temperature rating of not less then
167°F (75°C).
To Access Electrical Connections
Phillips Screwdriver Required