Caring for the Blender
Replacing the Cutter Unit Assembly
Replacing the cutter unit assembly
The cutter unit assembly should be checked daily
for worn, loose, or damaged blades. If the cutter
unit assembly is worn or damaged, it should be
replaced immediately.
1. Loosen the retainer nut on the bottom of
the container.
2. From the bottom of the container, press the
cutter unit assembly up into the container and
remove it. CAUTION--Blades are sharp!
3. Make sure that the gasket is properly seated
on cutter unit assembly, then install the new
cutter unit assembly in the bottom of the
container.
4. Tighten the retainer nut SECURELY, but do
not overtighten.
wWARNING
Cut Hazard
Always place cover on container when
blending.
Do not put hands, spoons, or other utensils
in container when blending.
Failure to follow these instructions can result
in broken bones, cuts, or other injuries.
Cutter Unit
Assembly
Retainer
Nut