Prolific Tech EFG 502 Cooktop User Manual


 
19
Grill burner
To replace the grill injector, follow this procedure:
Remove the grill burner after removing the
fixing screw.
Replace the injector by means of a No 10
socket spanner;
Refit all parts and test.
Flame adjustment
Oven burner
The burner is correctly adjusted when the flame is
stable, silent and goes out without any noise.
When the flames are too short, the injector is
whistling or the flames have the tendency to
detach from the burner, it means that there is
too much air in the burner. If there is too much
air there is a risk that the flames will extinguish.
But, if the flames are too long, soft, lighting,
there is not enough air in the burner. These
flames discolour the bottom of pans.
Loosen screw M which secures the air adjuster A;
Move the air adjuster A forward or backward
until achieving the right mixture (see table no.
2);
Tighten the securing screw M.
Grill burner
Loosen the screw securing the Venturi.
Move the adjusting collar left or right until
achieving the correct flame patten (see table no.
2).
Tighten the securing screw.
Adjustment of minimum level
Oven burn
Remove the pan support as well as the burner
caps and the burner crowns.
Unscrew and remove the 2 hob top fixing
screws and remove the hob top.
Light the burner to 250 degrees C and leave
the oven door closed for about 10 min.
Turn the thermostat control knob slowly to 150
degrees C.
Pull off the thermostat control knob to adjust
minimum flow.
Unscrew or screw the by-pass screw (it is
above the tap shaft) until a regular small flame
is reached.
For LPG screw the by pass screw in
completely
The flame shouldn’t extinguish when closing the
oven door.
Grill burner
The grill temperature cannot be adjusted. To obtain
a lower temperature or slower cooking time the grill
pan must be lowered away from the flame.
AFTER COMPLETION OF ANY REPAIRS,
ADJUSTMENTS OR CONVERSION THE STATUTORY
SAFETY TESTS MUST BE CARRIED OUT.
Table no.2
Air adjusting (mm)
Gas type
Oven Grill
G20 2,5 25,5
G30 3,5 24
G31 3,5 24
M
A
air adjustment
a
djustment collar screw