3.5 Dryer Transportation or Long-Term Storage
• Close inlet and outlet valves, switch off the devices (S1) and (ON/OFF), and disconnect power.
• Depressurize the air circuit using the condensate trap TEST button & remove the fill port plug to vent the reservoir.
• Drain the reservoir tank into a suitably sized container by removing right side panel (B) & turning drain valve (A) counter-
clockwise.
• Replace the fill port plug & close the drain valve (A) by turning clockwise.
4.0 MAINTENANCE
4.1 Weekly
• Visually inspect for proper condensate drain operation.
4.2 Monthly
• Isolate the dryer from the compressed air system by closing inlet & outlet valves and release pressure.
• Clean or replace condesate drain trap filter to remove any accumulated debris.
4.3 Semi-annually
• Check compressor electrical current draw against amperage listed on the data plate.
• Remove power from the dryer and clean condenser finned surfaces with compressed air jet.
5.0 EQUIPMENT DATA
Model
G5C-18 G5C-30 G5C-50 G5C-75 G5C-100 G5C-120 G5C-150 G5C-200 G5C-250 G5C-250
Capacity (scfm)* 18 30 60 75 100 120 150 200 250 250
Compressor Power (HP) 1/6 1/4 1/3 1/2 ¾ 1 1-1/2 1-1/2 2 2
Power Supply (V/Ph/Hz) 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 230/1/60 230/1/60 230/1/60 460/3/60
Rated Current (A) 1.1 3.7 5.2 6.8 8.1 9.2 7.5 7.5 8.5 3
Full Load Current (A) 2 4.6 6.8 8 9.8 11 8.7 10.5 12.5 5.2
Refrigerant Type R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a
Refrigerant Charge (LBS) 0.66 0.79 1.21 1.21 1.21 1.32 1.75 2.16 2.0 2.0
Connection Size F (NPT) 1/2 1/2 3/4 3/4 ¾ 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2
Weight (lbs) 66 77 119 132 141 203 232 232 247 247
Max. Air Inlet (°F) 113 113 113 113 113 113 113 113 113 113
Max. Ambient (°F) 104 104 104 104 104 104 104 104 104 104
Max. Pressure (psig) 230 230 230 230 230 230 230 230 230 230
*Rated capacity @ air inlet of 100°F & 100 psig, 100°F ambient & 33 – 39° F leaving dewpoint