Rangemaster E64000 Ventilation Hood User Manual


 
- 10 -
7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)
HD0271
Flip the blower and engage its
flange in the back wall retaining
bracket.
Using a 5/16” socket and the
screws previously removed, secure
the blower to the hood.
HD0272
8. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)
(INTERNAL BLOWER HOOD ONLY)
Using standard 3/8’’ screws provided,
secure the adapter to the top (or
back) of the hood (2 screws for a
3¼” x 10” adapter/damper and
4 screws for a 4½” x 18½” adapter).
Seal the adapter to the hood using
duct tape. For round ducting, install
an appropriate sized transition and
seal the joints with duct tape.
HJ0013
9. INSTALL ANKE60 RECIRCULATION KIT (NON DUCTED INSTALLATION ONLY)
Refer to the installation sheet included with the recirculation kit for details.
Slide the blower to disengage its flange from the
retaining bracket.
HD0270
LEFT SIDE
MOUNTING
SCREW
LOCATION
RIGHT SIDE
MOUNTING
SCREW
LOCATION
HE0085
Plug the blower in.
NOTE FOR DUAL BLOWER HOOD
ONLY: Cut off the plastic tie wrap on
left motor cable.