4-2-5. If defrost does not operate (F,R DEF Heater)
- If defrost has trouble, select the self-diagnostic function to detect the error of defrost heater before
Power Off. (Check the function with the self-diagnostic function)
R DEF ERROR F DEF ERROR
Start
Are the all deforst
heater normal?
Check the bimetal, heater
disconnection, wiring connection etc.
Refer to self-diagnostic
function in the manual
Replace the
applicable sensor
manual operation for a certain time
Manual defrosting of fresh food
and freezer compartments
operate simultaneously.
Resistance value of sensor according to temperature
If you need the
temperature with detail,
refer to DATA1.
temperature
table
**Measuring point of resistance value according to sensor **
F-DEF : CN30#4 CN76#1 measuring resistance value
R-DEF : CN30#8 CN76#1 measuring resistance value
** 0: Short trouble / : Open trouble
**Measuring point of resistance value according to heater**
F-DEF(Ice Duct parallel) : CN70#7(Brown) CN71#9
(Orange) measuring resistance value(55 ohm 7%)
R-DEF : CN70#5(White)N71#9(Orange)
measuring resistance value(110 ohm 7%)
** 0: Short trouble / : Open(bimetal, heater) trouble
86(30)
68(20)
50(10)
32(0)
14(-10)
-4(-20)
-22(-30)
4.22
6.05
8.87
13.29
20.42
32.23
52.41
If Energy Saver + Fridge key are pressed
simultaneously for 8 seconds and select any key.
4thtest mode(manual defrosting will be operated).
Is the temperature of
defrost sensor lower
than 53.6(12°C)?
Is defrost sensor by
self-diagnostic normal?
Is power applied to
each defrost heaters?
Is connection terminal of
MAIN PCB part normal?
Recheck the applicable
sensor.
**Measuring point of resistance value according to sensor **
F-DEF : CN30#4 CN76#1 measuring resistance value
R-DEF : CN30#8 CN76#1 measuring resistance value
** 0V: Short trouble / 5V: Open trouble
Normal
Repair connection terminal
Reference If defrost sensor
temperatures of fresh food and
freezer compartments are higher
than 50(10), 53.6(12) by
the heating from heater, heating
would be finished and will return
to cooling operation after a pause.
Check bimetal, heater itself,
disconnection etc.
Replace failure Relay or
replace PCB ASS'Y
Does the system return
to cooling operation after
heating for specified time?
Checking method of F,R DEF Heater resistance value
F DEF ; CN70#7(Brown) CN71#9(Orange)
R DEF ; CN70#5(White) CN71#9(Orange)
-
Recheck if resistance values are different after the test
1) F DEF Heater 2) R DEF Heater
    