Samsung RS2630W/XAA Refrigerator User Manual


 
21
Function & How- to-use By Products
1) Button TOUCH
1-1) When selecting each button in the CONTROL PANEL, the verification sound (Ding Dong) of input shall
be heard.
1-2) In the case of pressing more than two KEYS at the same time or pressing the wrong button, the sound
shall not be heard.
2) DOOR-OPEN
2-1) After passing 2 min. consecutively as Freezer/Refrigerator DOOR opened, SOUND alarm (Ding Dong)
shall be heard.
2-2) If the door is still open afterward, sound alarm will be circulated to SOUND (Ding Dong) generating
movement at the interval of a min.
2-3) Alarm stops when Freezer/Refrigerators are all closed.
1) In the case of instant power failure and initialization of PANEL DISPLAY, these can make customers NON-
SENSE CALL. To avoid this, if power is applied, it judges the temp of Freezer and operates as either
initialization or restoration of operation conditions.
2) With initial POWER ON, it judges the temp of Freezer and if it is below (+41°F/+5°C), it is judged as instant
power failure while operating and restoring the functions related to PANEL DISPLAY such as Power freezing,
CHILD LOCK and Freezer/Refrigerator settings.
3) With initial POWER ON, it judges the temp of Freezer and if it is above (+41°F/+5°C), it is judged as extended
power failure and PANEL DISPLAY will be initialized (Automatic setting at (-4°F/-20°C) for Freezer and
(37.4°F/3°C) for Refrigerator).
When pressing Refrigerator temp set KEY and ICE TYPE KEY in PANEL PCB simultaneously for more than
8 sec. PANEL DISPLAY will go off and it moves onto TEST MODE. At this point, although
Freezer/Refrigerator temp set KEY, Power freezing KEY, and ICE TYPE KEY are pressed, it operates by
TEST KEY.
When pressing TEST KEY, Test function shall be changed in the order as Forced Operation ---> Forced
Freezer Defrost---> Cancellation(normal operation)---> Forced Operation. If functions are canceled during the
operation of TEST function, it is most desirable to turn off the power and turn it on again.
7-9) ALARM
7-10) RESTORATION OF OPERATION CONDITIONS FOR POWER FAILURE
7-11) TEST (FORCED OPERATION / FORCED DEFROST)
Press for 8 sec
RS2630SW/XAA (for Best Buy)