Sanyo CHDXR09663 Refrigerator User Manual


 
1
(1)
(2)
High-pressure sensor failure
This system contains 2 types of pressure sensors: a high-pressure sensor and a low-pressure sensor.
Alarms are emitted when the high-pressure sensor becomes an electrical open-circuit or a short-circuit condi-
tions, and a broken wiring, short-circuit or poor connection to the PCB in the high-pressure sensor circuit.
Low-pressure sensor failure
Alarms are emitted when the low-pressure sensor becomes an electrical open-circuit or a short-circuit condi-
tions, and a broken wiring, short-circuit or poor connection to the PCB in the low-pressure sensor circuit.
Alarm display
High-pressure sensor failure Low-pressure sensor failure
F16 F17
1 - 27
W-2WAY ECO-i SYSTEM
Control Functions
15. Pressure Sensor Failure