Sanyo MPR-411FR Refrigerator User Manual


 
17
TEMPERATURE RECORDER
Attachment of temperature recorder
For refrigerator
1. Attach the fixture to the temperature recorder with
two screws. (Fig. 1)
2. Remove the screws at the right corner on the top of
the unit and fix the recorder to the position. (Fig. 2)
3. Remove a rubber cap and insulation covering the
access hole on the back of the unit.
4. Take the recorder sensor into the refrigerator
chamber through the access hole.
5. Fix the recorder sensor on the right wall of the
chamber with the enclosed clips (large). (Fig. 3)
6. Make a cut on the rubber cap and route the lead wire
through it. (Fig. 4)
7. Cover the access port with the insulation and rubber
cap.
For freezer
1. Remove a cap for the fixing screw on the cover for
mounting space of temperature recorder.
2. Remove the fixing screw and open the panel. (Fig.
5)
3. Remove the panel by pushing the shaft on both side
outward and remove the panel fixture.
4. Attach the temperature recorder (MTR-4014LH) to
the recorder fixture [MDF-53RO (H)] by using the
enclosed screws. (Fig. 6)
5. Remove a rubber cap and insulation covering the
access port on the back of the unit.
6. Take out the recorder sensor from the back of the
unit through the mounting space.
7. Pass the sensor through the access port of the
freezer. The length of the capillary inside the freezer
should be about 40 cm.
8. Fix the recorder sensor on the left wall of the
chamber with the enclosed clips (small). (Fig. 7)
9. Make a cut on the rubber cap and route the lead wire
through it. (Fig. 4 above)
10. Cover the access port with the insulation and rubber
cap.
11. Fix the extra capillary tube to the back of the
recorder with the enclosed clip and screw. (Fig. 8)
12. Mount the recorder fixture to the mounting space in
the unit. (Fig. 9)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9