Sanyo STB0810C1 Cooktop User Manual


 
45
10-2. Defrosting Operation (Heating)
Defrosting Flowchart
Defrosting Mode Timing Chart
Once the air conditioner enters defrosting mode, it will not release defrosting until the
outdoor heat exchanger coil temperature rises above 39°F. During this period, heat is
provided by electric heater instead of by the heat pump.
NOTE
Outdoor heat
exch coil
temp.
Release of defrostingStart of defrosting
39 °F
14 °F
ON
Solenoid coil
(4-way valve)
Compressor
OFF
ON
ON
ON
Electric heater ON
ON
Fan motor
OFF OFF
Set speed
YES
YES
Temperature of outdoor heat
exchanger coil is blow 14°F.
Temperature of outdoor heat
exchanger coil is higher than
39°F.
Defrosting begins
Compressor ON
Release of defrosting
NO
NO
Compressor
OFF
Electric Heater
ON
Heat Pump Model
Model STB0823H1