Cleaning, Sanitation and Maintenance
This ice system requires three types of
maintenance:
Remove the build up of mineral scale from the ice machine’s water system and sensors.
Sanitize the ice machine’s water system and the ice storage bin or dispenser.
Clean the remote condenser.
It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition. Without
human intervention, sanitation will not be maintained. Ice machines also require occasional cleaning of
their water systems with a specifically designed chemical. This chemical dissolves mineral build up that
forms during the ice making process.
Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine
is cleaned and sanitized.
The ice machine’s water system should be cleaned and sanitized a minimum of twice per year.
1. Remove the front panel.
2. Remove the evaporator cover.
3. If the machine is operating, push and release
the Harvest button. When the machine
completes the Harvest cycle it will stop. If the
bin is full (b shows in display) push and release
the Off button.
4. Remove all ice from the storage bin or
dispenser.
5. Push and release the Clean button. The yellow
Clean light will blink and the display will show
C. The machine will drain the reservoir and refill
it. Go onto the next step when the reservoir has
filled.
6. Pour 8 ounces of Scotsman Clear 1 ice
machine scale remover into the reservoir.
7. Allow the ice machine scale remover to
circulate in the water system for at least 10
minutes.
8. Push and release the Clean button again. The
yellow Clean light will be on continuously and
the machine will drain and refill the reservoir to
flush out the ice machine scale remover and
residue.
9. Allow the drain and refill process to continue for
at least 20 minutes.
10. Push and release the Off button. The clean
cycle will stop and the display will show O.
Note: if the machine has not been de-scaled for an
extended period of time and has significant mineral
scale remaining, repeat steps 5-10.
11. Mix a cleaning solution of 1 oz of ice machine
scale remover to 12 ounces of water.
12. Locate curtain, push in on edge of curtain by
pivot pin to release it. Pull each curtain out of
machine.
July 2006
Page 21
C0522 through C1030
Remote Condenser Models - User Manual
Ice machine cleaner contains
acids. Acids can cause burns.
If concentrated cleaner comes
in contact with skin, flush with
water. If swallowed, do NOT
induce vomiting. Give large
amounts of water or milk. Call
Physician immediately. Keep
out of the reach of children.
Pull Here
Push Here