Sears 249R Refrigerator User Manual


 
_ IIIIII11 II({I I 'IH I I I
_o- ,,,,H,H,,H, III" .... ' .............. l'll I
PRODUCT OPERATION
The importance of the Installation of
your Sub-Zero CANNOT be
overemphasized. The proper
installation of your unit is the
responsibility of the selling dealer or
installer. Any questions or problems
pertaining to the installation should be
directed to the selling dealer.
TEMPERATURE
CONTROL LOCATION
AND ADJUSTMENTS
- Your new refrigerator and/or freezer was
thoroughly inspected and tested before it
was shipped from the Sub-Zero factory.
During these procedures, the temperatures
were preset to maintain approximately 38
degrees in the refrigerator section and
approximately 0 degrees in the freezer
section (except 249R). Ifyou wish to make
temperature adjustments, simply turn the
temperature control dial. The higher the
number the colder the temperature (#1 is
the warmest and #7 is the coldest setting).
For the location of the control, refer to the
model of your Sub-Zero on the following
pages.
You should be aware it is normal for the
above temperatures to fluctuate slightly,
depending on external influence such as:
open door for extended periods, the
degree of humidity present and room tem-
perature.
.4) ADJUSTMENT
To adjust the freezer and refrigerator
controlson our models 245, 249R, 249RP,
249FF and 801RFD, simply turn the control
knob so the indicator lines up with the
desired number.
B) LOCATION
MODEL 245
The freezer control is located on the back
wall above and right of the ic_emaker
assembly. (See Model 245 Features on
page 3.) The refrigerator control is situated
left of center at the top of the refrigerator
compartment. (See Model 245 Features on
page 3.)
MODEL 249R
(MANUAL DEFROST)
The control issituated on the right hand
side of the back wall in the upper freezer
corn artment. See
pageant.) 1._ Model 249RP Features
on
MODEL 249RP
The control is located on the right side of
the back wall just below the lower shelf
assembly. (See Model 249RP Features on
page 3.)
MODEL 249FF
The control is found at the top of the freezer
on the right side of the defrost blower
assembly. (See Model 249FF Features on
page 4.)
MODEL 801 RFD
The refrigerator control is located on the top
left wall of the refrigerator compartment as
you face the unit. (See Model 801 RFD
Features on page 4.) The freezer control is
situated on the right side of the automatic
defrost blower assembly located at the top
of the freezer compartment. (See Model
801RFD Features on page 4.)
DOOR CLOSING
MODELS 245 and 801RFD
The doors on our models 245 and 801RFD
are equipped with a door closing cam
system to assist in the closing of the door.
As you close the door, the cam will take
over at approximately the 15 degree posi-
tion to assist in the closing of the door.
MODELS 249R, 249RP and 249FF
The refrigerator and freezer doors are both
equipped with a spring-loaded door clo-
sure mechanism. As the doors are closed,
the door closure engages at approximately
the 15 degree position to assist the door in
closing and sealing.
CONDENSER FAN
OPERATION
All undercounter units have one fan located
behind the kickplate at the base of the unit.
On all undercounter models the fan
operates on/ywhen the compressor is run-
ning.
EVAPORATOR FAN
OPERATION
MODELS 245, 249FF and 801RFD
A fan motor islocated in the freezer section
on the models listed above. These fans
operate onlywhen the compressor is
running.
AUTOMATIC DEFROST
INFORMATION
For your convenience, Sub-Zero has
equipped the following models with an
automatic defrost system: 245, 249RP,
249FF and 801RFD. NOTE: Our model
249R is not equipped with automatic
defrost. To manually defrost, turn the a
control knob to the off position.
SOUNDS
Certain noises may be evident with the
normal operation of the unit. Surrounding
acoustics like walls, floors and cabinets
may affect the sound level of your unit.
A gurgling sound or running water sound
may be evident as the refrigerant circulates
through the tubing.
During the icemaker cycle, you may hear
the sound of ice dropping into the bucket
or the solenoid valve while refilling the ice-
maker with water.
During the freezer defrost, you may hear
crackling and/or sizzling as the heat from
the defrost element clears the frost from the
freezer coil and water runs into the defrost
water pan.
While the compressors are in operation, a
slight hum might be evident. During the
startup and shutdown of the compressor,
some vibration may occur lasting only a
few seconds.
ICEMAKER OPERATION
The icemaker in your Sub-Zero is fully auto-
matic and has been factory pretested. To
put into operation, it requires only a con-
nection to the house water supply.