Sears 625.34929 Water Dispenser User Manual


 
ELECTRICAL WgRRNG GUIDE,
A CAUTION: DO NOT TRY TO DO ANY
WIRING IF YOU DO NOT KNOW ELEC-
TRICITY. CALL A GOOD ELECTRICIAN
A CAUTION: DO NOT DO ANY WIRING ON
LIVE CIRCUITS ALWAYS TURN OFF THE
ELECTRICAL POWER AT THE SOURCE,
NOTE: All wiring must follow local or national
electrical codes.
1. Looking at FIG.7and8or9, installand wire
in a duplex, 3-prong, 115 volt grounded
" outlet Be sure to connect the outlet through
the well pump pressure switch so the solution
pump runs only when the well pump is on
,_ CAUTION: Many well pumps work on 230
volts. DO NOT CONNECT THE SOLUTION
PUMP TOA230VOLTCIRCUIT, Connectto
only 1 leg of a single phase 230 volt circuit, as
shown in FIG 9.
2, Turn on the electrical power at the source DO
NOT plug in the power cord this time. First, fill
the storage tank with solution (page 12).
115 VOLT OUTLET
Wall
Receptacle
Conduit -_
WIRING DIAGRAM - 115 VOLT SYSTEM
Duplex. 3-prong Solution
Electrical Outlet Pump
Well n Pump
Pump Power Cord
_'N Pump
Pressure
Switch
115V
From
115V Power
Source
WIRING DIAGRAM - 230 VOLT SYSTEM
Solution Pump Solution
Power Cord Pump
Well
Pump
L 1 Star Neutral
L1 230V
L2 Power
Souse
230V
Control
Box
or
Pressure
Switch
11