Sears 625.34929 Water Dispenser User Manual


 
WHERE TO LOCATE YOUR
Locate the system where...
......a 115 volt, 60 Hz electrical power source is
nearby. (See page 11)
...good fresh air flow will cool the solution
pump motor and carry away solution fumes.
..... the area is clean and the air is free of dust.
A _ .the solution pump and tank are easy to
reach for servicing and refilling, BUT
OUT OF THE REACH OF CHILDREN
A
.... IT'S AWAY FROM DIRECT SUNLIGHT
DAMAGE FROM SOLUTIONS, DUE TO
LEAKS THAT COU LD OCCUR, IS LEAST
LIKELY
it's close to the solution injection point
Read about the 3 ways to inject solution,
below.
PiCK THE BEST WAY TO INJEI
Chlorine or neutralizer feeding is done in 1 of 3
ways with the solution dispensing system Read
the following and pick the best way to treat your
water supply..
(#
Chlorine or neutralizer injected right into
the well casing (FIG. 2, below and FIG. 4,
page 8) - This is the best way to feed
chlorine.
(_) Chlorine or neutralizer injected into the
alternate discharge fitting on the well pump
(FIG. 2 and FIG. 5, page 9)-This is the best
way to feed neutralizer.
(_) Chlorine or neutralizer injected at some
point between the well pump and pressure
tank (FIG. 2 and FIG 6, page 10).
IMPORTANT: When the well pump is running,
the solution feed pump is feeding chlorine or
To Household
ULC
Water Pressure
Filter Tank
neutralizer into the water.. For the chlorine or
neutralizer to work right, it must mix with the
problem water for a short time. With today's
fast recovery water pumps and direct fresh
water drawing, most water bypasses the
pressure tank.. This does not allow enough
time for good solution mixing to treat the pro-
blem water. If you have a fast water pumping
system*, you must install a 42 gallon (or larger)
blending tank, as shown in FIG. 3, to get the
needed mixing time. A blending tank is avail-
able from Sears, Stock No. 42.34028o
NOTE: In 90 to 95% of all Solution Dispensing
System installations, a blending tank is needed
for proper Solution mixing° A blending tank is
helpful in all installations, but in some (shallow
well, long piping runs, feeding neutralizer com-
pound only) it could be left out under certain
conditions° Talk to your Sears sales depart-
ment for help.
)
I From Well
I
(_ SOLUTION INJECTION INTO THE
WELL CASING-- PAGE 8
(_) SOLUTION INJECTION INTO THE
WELL PUMP ALTERNATE DIS-
CHARGE FITTING -- PAGE 9
(_) SOLUTION INJECTION BETWEEN
THE WELL PUMP AND PRESSURE
TANK-- PAGE 10
CAUTION: CHLORINE, INJECTED INTO THE WATER, MAY SHORTEN THE LIFE OF GASKETS AND SEALS IN YOUR WATER SYSTEM
7