INTRODUCTION
The SmarTire LF Initiator is a handheld tool designed to provoke data transmissions from SmarTire
High Pressure Sensors. The tool can be used to assist the installer during:
New Installations – programming sensor ID numbers & vehicle configuration into the
receiver
Sensor Replacement - programming new sensor ID numbers into the receiver
Installation Verification (without moving vehicle)
Transmitter De-Activation (after removal)
NOTE: The SmarTire LF Initiator is compatible with SmarTire’s low and high pressure
commercial sensors ONLY. It is not compatible with the low pressure sensors used in
SmarTire products for passenger vehicles, motorcycles, trailers and tow-behinds.
OVERVIEW
Initiate: Press this button to make a sensor transmit its ID number, tire pressure data and tire
temperature data. This function is used when confirming that sensors are installed in the correct
wheel locations on a vehicle after system installation.
De-energize: Press this button to de-activate a sensor. This function should only be used when
sensors are removed from a vehicle.
Initiate Button
De-Energize Button
Learn Button
Battery Cover
LED Light
Transmission End
On / Off Switch