Smeg A1XCU6 Range User Manual


 
Instructions for the Installer
14
5.2 US installation and canadian installation / 4-wire branch circuit
Refer to picture 2,
- The ground wire must be attached first;
- Connect the green or yellow-green ground wire
from the appliance to the ground in the junction
box (green colored wire). Do not connect
grounding wire to neutral wire in junction
box.
- Connect the red leads from the appliance to the
corresponding leads in the junctionbox.
- Connect the white wire from the appliance to the
neutral (white colored wire) wire in the junction
box.
pic.2)
NOTE: FOR MODEL RATED UP TO 4.3 KW CONNECT TO A 20A FUSE OR CIRCUIT BREAKER;
FOR MODEL RATED FROM 4.4 KW TO 6.6 KW CONNECT TO A 30A FUSE OR CIRCUIT BREAKER;
FOR MODEL RATED FROM 6.7 KW TO 8.8 KW CONNECT TO A 40A FUSE OR CIRCUIT BREAKER;
FOR MODEL RATED FROM 8.9 KW TO 11.0 KW CONNECT TO A 50A FUSE OR CIRCUIT BREAKER.
FOR BOTH US AND CANADIAN INSTALLATION: THIS APPLIANCE IS EQUIPPED WITH COPPER
LEAD WIRES AND MUST BE CONNECTED TO COPPER WIRES ONLY. ALUMINIUM WIRES MUST
NOT BE USED.
NOTE: Both power cables coming out of the cooker, must be connected according to the diagrams
shown in pictures 1 and 2