Instructions for the Installer
9
4. WALL FIXING AND ANTI-TIP DEVICE
WARNING
- All ranges can tip
- Injury to persons could result
- Install anti-tip device packed with the range
- See installation instructions
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR
SERIOUS BURNS TO CHILDREN OR ADULTS.
WARNING
ELECTRIC SHOCK HAZARD
- Use extreme caution when drilling holes into the wall or floor. There may be
concealed electrical wires located behind the wall or under the floor.
- Identify the electrical circuits that could be affected by the installation of the
Anti-Tip Device, then turn off power to these circuits.
- Failure to follow these instructions may result in electrcal shock or other
personal injury.
CAUTION: PROPERTY DAMAGE
- Contact a qualified installer or contractor to determine the proper method fro drilling holes through the
wall or floor material (such as ceramic tile, hardwood, etc.)
- Failure to follow these instructions may result in damage to wall or floor coverings.
4.1 Instructions for wall mounting
The anti tip brackets are to be attached to the rear wall as shown. The height of the bracket location from
the floor is determined after the range legs have been adjusted to the installation height as shown in the
installation instructions and the range has been leveled.
1 Level the range
using the front
adjustable
leveling legs.
2 From the floor,
measure the height
of the notch found
on the bracket. This
notch corresponds
to the centerline of
the holes for the
screws that will
fasten the brackets
to the wall.