Smeg A2-5 Cooktop User Manual


 
Instructions for the installer
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.05 50 30 360 76 75
Semi rapid
1.8 65 33 450 131 129
Rapid
3 85 45 750 218 215
Triple crown
3.3 91 68 1600 240 236
Burner
Rated heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle
diameter
1/100 mm
Reduced
flowrate
(W)
Auxiliary
1.05 72 360
Semi rapid
1.8 97 450
Rapid
3 115 750
Triple crown
3.5 133 1600
3.3 Arrangement of burners on cooking hob
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra rapid
5 Ultra rapid
4. FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the
burner caps and the grids.
After adjustment to a different kind of gas from the one for which the
cooker has been tested, replace the plate inside the storage
compartment with one corresponding to the new kind of gas. This plate
can be obtained from your nearest Authorised Assistance Centre.
43