Smeg A36A6PXAA Range User Manual


 
Instructions for the installer
Do not use reducers, adapters or shunts.
If the power cable is replaced, the wire section on the new cable must
not be less than 0.75 mm
2
(3 x 0.75 cable), keeping in mind that the end
to be connected to the hob must have the ground wire (yellow-green)
longer by at least 20 mm. Use only H05V2V2-F cable or similar which has
a maximum temperature of 90°C. Any replacement needed should be
carried out by a specialised technician who should make the mains
connections according to the following diagram.
L = brown
N = blue
= yellow-green
The manufacturer will not be liable for any damage to persons or
property caused by non-observance of the above instructions or deriving
from the tampering of even a single part of the hob.
2.3 Ventilation of rooms
The hob may be installed only in rooms with permanent ventilation, as
required by standards regulations in force. The room in which the hob is
installed must have sufficient air flow to satisfy the requirements of
normal gas combustion and of necessary air exchange in the room. The
air intakes, protected by screens, must be appropriately sized
(regulations in force) and placed so as not to be blocked in any way.
The room where the oven is installed should be suitably ventilated to
avoid overheating or excess humidity produced by cooking, and in the
case of lengthy use a window should be opened or the speed of any
ventilators should be increased.
2.4 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of
hoods connected to a natural draught flue with certain efficiency, or by
means of forced aspiration. An efficient aspiration system requires
careful planning by a specialist capable of installing it, respecting the
positions and distances prescribed by standards. After installation, the
installer must issue a certificate of conformity.
19