Smeg ALFA141VE Oven User Manual


 
25
Instructions for the installer
When linking up to mains by plug and socket, the connection must be
completed with a three-core plug of adequate capacity (25A), or, for
operation at 380-415V2N or 380-415V3N, a five-core plug (16A). The
plug and wall-mounted socket must be of the same type (in accordance
with CEI regulations). Make sure that the supply line is suitably earthed.
Avoid use of adapters and shunts.
If the appliance is connected to the electrical mains supply in a
permanent manner, install a multipolar cut-out device on the line, with
contact opening distance equal to or greater than 3 mm located near the
appliance and in an easily reachable position.
WARNING: if the phase voltage drops below 190 VAC, the performance
of the oven may suffer, not due to the product itself.
The terminal marked with this symbol connects parts together that are
normally at zero potential. Connect the appliances appropriately using
this terminal in order to make sure that they are equipotential.
2.1.1 Safety thermostat
The oven is equipped with a safety device that takes action in case of
serious malfunction. To re-arm the safety device you must contact the
technical assistance service.
The manufacturer declines all responsibility for damage to persons
or things caused by the non-observance of the above prescriptions or
deriving from tampering with any part of the appliance.
2.2 Levelling
Level the oven on the ground using the four adjustable feet. In order to
adjust them, loosen the lock nut and unscrew the foot. The adjustment
screws have a range of 10 mm.