Smeg ALFA41AM Oven User Manual


 
Instructions for the installer
24
3. OVEN INSTALLATION
The oven must be set up on a perfectly flat surface and left standing
free. Make sure to allow enough room at the back for easy access to the
terminal strip for connecting the power supply cable. Installation must be
carried out by a qualified technician in compliance with EEC
DIRECTIVES currently in force.
3.1 Electrical connection
Make sure the voltage and the cross-section of the power cord match the
specifications indicated on the identification plate positioned on the side of
the oven. Do not remove this plate for any reason.
The oven is fitted with an H07RN-F three-core cable for operation at
230V and a power supply plug.
The supplied cable is of the three-core 3 x 1.5 mm
2
H07RN-F type.
The power supply cable must be replaced by the manufacturer or by an
authorised service centre to prevent any risks.
The terminal marked with this symbol connects parts together that are
normally at zero potential. Connect the appliances appropriately using
this terminal in order to make sure that they are equipotential.
The plug and wall-mounted socket must be of the same type (in
accordance with current regulations). Also check that the power supply
line is provided with adequate earthing. Avoid use of adapters and
shunts.
3.1.1 Safety thermostat
The oven is fitted with a safety device which trips in case of serious
malfunction. To reset, contact the nearest technical assistance centre.
The manufacturer declines all responsibility for damage to persons
or things caused by the non-observance of the above prescriptions or
deriving from tampering with any part of the appliance.